The Deltic Group Inc.
Home | Aviation |
Defense and Security |
Marine | Contact |
Portasonc® FL0 Clamp-on Ultrasonic Liquid in Pipe Flow Meter
![]() |
![]() |
The Portasonic® 2.FL0 flow meter, for measuring the volumetric flow rate of clean liquids in pipes.
The Portasonic® 2.FL0 is a handheld ultrasonic flow meter for testing on an wide variety of different pipe dimensions, liquid types, measurement methods, flow speeds and environments. The unit has a straightforward testing process with a step by step guide on how to set your flow meter up before measuring. The user simply needs pipe diameter, wall thickness and liquid type information, to be able to easily and accurately measure flow rate.
Portasonic® 2.FL0 flow meter from Coltraco
Type – 2nd Generation Portable
Ultrasonic Flow Meter
Part Number – PS012
Sensors available for a range of pipe diameters. For
fluid temperature exceeding 90°C, high temperature sensor available up to 160°C.
For installation in tight spaces, please note the sensor dimensions below. Loose
sensors can be supplied if options below are too large:
Portasonic®2.FL0 sensor options
SMALL SENSOR
No mount*
Pipe diameter range: 15mm – 100mm
Sensor dimensions: 45mm x 25mm x32mm
With mount
Pipe diameter range: 15mm – 100mm
Sensor dimensions: 318mm x 59mm x 85mm
Operating temperature: -30C to 90C
MEDIUM SENSOR
No mount*
Pipe diameter range: 50mm – 700mm
Sensor dimensions: 64mm x 39mm x44mm
With mount
Pipe diameter range: 50mm – 300mm
Sensor dimensions: 568mm x 59mm x85mm
Operating temperature: -30C to 90C
LARGE SENSOR
No mount*
Pipe diameter range: 300mm – 6000mm
Sensor dimensions: 97mm x54mm x53mm
Operating temperature: -30C to 90C
*For sensors without mount, jubilee
clips are provided to secure the sensors to the pipes.
Specifications:
Linearity
0.5%
Repeatability
0.2%
Accuracy
±1% of reading at rates >0.2m/s
Response Time
0-999 seconds user-configurable
Maximum Velocity
±32 m/s
Pipe Size
15mm-6000mm (different sensors available for different pipe sizes)
Totalizer
Net, Positive and Negative Flow
Liquid Types
Will work on most types of non-aerated liquids with low solid particle content
such as water, sea water and most oils.
Display
LCD display with 4 x 16 Letters
Communication Interface RS232
Transducer Cable Length Standard 5m x 2,
optional 10m x 2
Power Supply
3 AAA built-in, non-removable NiH 2000 mAh batteries. Lasts up to 12 hours of
operation when fully charged.
Data
Logger
Built-in data logger can store over 2000 lines of data
Housing Materials
Black Anodised Aluminium (Casing), ABS Plastic (Sensors), Aluminium (Guide
Rails)
Main Unit Dimension
225mm (Height) x 110mm (Width) x 35mm (Depth)
Main Unit Weight
650g with batteries